BioQuant-96 BIOSAN is the newest product of Biosan Molecular diagnostic product family.
It has adopted innovative thermoelectric refrigeration technology, a brand-new light source, and a light path design. Detection from the top allows using different consumables – 0,2 tubes, 8-tube strips, and semi-skirted and non-skirted 96-well PCR plates. The unique constant current power and 6-zone independent temperature control method ensures more rapid, correct, and stable fluorescence quantitative analysis while maintaining its excellent performance in the lowest possible energy consumption.
The device is available in 5-channel and 6-channel configuration. Meanwhile, it has been added with functions including independent temperature control, low-temperature storage of sample at 4℃, and FAST mode for faster cycling (confirm reagent compatibility with fast mode).
BioQuant-96 BIOSAN is comprehensively realizing automatic gain settings and improving user experience. It will fully meet the demand of scientific research laboratories and registered as I (A) class Medical device in the EU it also will fully meet the requirements of any diagnostic laboratory.
BioQuant-96 Biosan Specification
| Sample capacity | 0.2ml single tube (transparent cap), 96×0.2(0.1)ml Plate (transparent cap), 8-strip tubes (transparent cap) |
|---|---|
| Dynamic range | 1~10^10 copies |
| Excitation wavelength | 300-800 nm |
| Emission wavelength | 500-800 nm |
| Channels | 5 |
| Temperature setting range | 4 ~105°C (increment: 0.1°C) |
| Heating/coolling rate | Max 6.0 °C/s / 5.5 °C/s |
| Temperature accuracy | ≤±0.1°C |
| Temperature fluctuation | ≤±0.3°C |
| Temperature uniformity | ≤±0.3°C |
| Temperature control mode | Block/6-zone gradient |
| Sample volume | 5 ~ 100 μl |
| Gradient temperature range | 1 ~ 36°C |
| Hot-lid temperature range | 30 ~110°C (adjustable default: 105°C, Automatic Hot-lid) |
| Repeatability | 5% |
| Scan mode | Full plate simultaneously |
| Program | Max. 20 segments for each program, max. 99 cycles |
| Continuous operation | + |
| Scan period | 5.5 s |
| Software | BioQuant-96 Software |
| Operating system | Windows 7/8/10 |
| Software required | Microsoft Excel |
| Minimum PC requirements | Built-in touchscreen PC / Memory: 512MB, Hard Disk:10GB, CPU: Pentium® 4, Virtual Memory: ≥1000MB |
| Nominal operating voltage | 100-240V; ~50/60Hz |
| Power consumption | 600W |
| Dimensions (W×D×H) | 490×290×391 mm |
| Number of sockets | USB adapter, Bluetooth adapter |
| Certification | CE-IVD |
| Interface | WIN 10 on built-in touchscreen PC |
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.